UI Test Cases for Edit Menu

Preconditions

Test Case ID

Instructions

Expected Results

Date Executed

Pass/Fail

Click on Edit from the toolbar

E1

1. Select the Editor tab from the Control Panel and add two nodes to a blank space on the network canvas
2. Drag and select both nodes
3. Click Connect Selected Nodes

An edge connecting the two new nodes should appear

E2

1. Drag and select the new nodes and edge
2. Click Delete Selected Nodes and Edges

The selected nodes and edges should no longer appear on the network canvas

E3

Click Undo: Delete

The nodes and edge deleted in E2 should reappear

E4

Click Redo: Delete

The nodes and edge should be deleted again

E5

1. Select a network from the Network tab in the Control Panel
2. Click Destroy View

The network canvas window should be deleted

E6

1. Select the same network as in E5
2. Click Create View

The network canvas window should appear with the network displayed in its default state

E7

Click Destroy Network

The network canvas window should be gone and the Network tab on the Control Panel should not show the network deleted

E8

Click on Preferences option, select Properties

'Cytoscape Preference Editor' window should show up

E8.1

(Continuation from E8) - Click on the add button. Add a name and a value

Ensure the property name and value show up in the list

E8.2

(Continuation from E8) - Click on the "Modify" button. Edit the name and/or value

Ensure the changes are reflected on the list

E8.3

(Continuation from E8) - Choose the above created property and click on the Delete button

The property should get deleted

E8.4

Click on the Preferences menu, select Bookmark

Ensure the bookmark window opens up

E8.5

Click on the preferences menu; add, edit or delete a bookmark

Ensure you are able to add, edit or delete the bookmark

E8.6

Click on the preferences menu; Select proxy. The add proxy window opens up; try adding a proxy

Ensure you are able to add a proxy

UI Test Cases for View Menu

Preconditions

Test Case ID

Instructions

Expected Results

Date Executed

Pass/Fail

1. Start Cytoscape
2. Import a network file (eg. galFiltered.sif)
3. Click on View from the toolbar

V1

Click Hide Control Panel

The Control Panel should now be hidden and can be restored by clicking Show Control Panel

V2

Click Hide Data Panel

The Data Browser Panel should now be hidden and can be restored by clicking Show Data Panel

V3

Click Hide Results Panel

The Results Panel should now be hidden and can be restored by clicking Show Results Panel

V4

1. Zoom out until you can't see the labels on individual nodes any longer.
2. Click Hide Graphics Details.

Things like the node labels should no longer be visible when zoomed out past a certain point

V5

With any other tab in the Control Panel selected apart from the Vizmapper™ click the Open Vizmapper™ button

The Vizmapper™ tab in the Control Panel should now be open

V6.1

1. Ensure that there are three different network windows open
2. Select Arrange Network Windows → Cascade

The network windows should be arranged slightly overlapping and filling the entire view area

V6.2

1. Repeat step 1 from V6.1
2. Select Arrange Network Windows → Tiled

The network windows should not overlap but should fill the entire view area in a tiled pattern

V6.3

1. Repeat step 1 from V6.1
2. Select Arrange Network Windows → Horizontal

The network windows should not overlap but should span the width of the view area one above another

V6.4

1. Repeat step 1 from V6.1
2. Select Arrange Network Windows → Vertical

The network windows should not overlap but should span the height of the view area one beside another

V6.5

1. Repeat step 1 from V6.1
2. Select Arrange Network Windows → Default

The network windows should overlap each other completely and are positioned in the top left hand corner of the view area